NO | 74 |
---|---|
Acronym | UNIURB |
Name | University of Urbino, Dep. of Pure and Applied Sciences (DISPEA) |
Address 1 | piazza Rinascimento 6 |
Address 2 | 61029 - Urbino |
Address 3 | |
Country/Territory | Italy |
Website |
Name | Jgor Arduini |
---|---|
Prefix | Dr. |
jgor.arduini@uniurb.it | |
Organization No | 74 |
Organization acronym | UNIURB |
Organization name | University of Urbino, Dep. of Pure and Applied Sciences (DISPEA) |
Organization country/territory | Italy |
Address 1 | |
Address 2 | DISPEA |
Address 3 | piazza Rinascimento 6, 61029 Urbino - Italy |
Country/territory | Italy |
Tel | 00390722303316 |
Fax | 00390722303311 |
Last updated date | 2024-07-25 |
Background observation | |
UTC+01:00 | |
ppt | |
9999-12-31 00:00:00 - 9999-12-31 23:59:59: WMO SF6 X2014 |
|
9999-12-31 00:00:00 - 9999-12-31 23:59:59: Agilent GC6890(Gas chromatography (ECD)) |
|
9999-12-31 00:00:00 - 9999-12-31 23:59:59: 7 (m) |
|
30 minutes | |
every 15 minutes a sample is analyzed alternating between real air and reference standard in order to correct for short time instrumental drifts. molar fraction is calculated from the ratio of the peak heights; reference standard (local working standard) is regolarly checked against NOAA cylinders |
|
reported data are single point, no average is computed; data validation is evaluated by checking the correct instrumental operation, the spread of the repeated working standard analysis; in case of anomalies, real data are flagged for a deep check and -eventually- removed form the final dataset. results from target cylinder is used to check for long term stability of the whole set up and eventually correct or remove suspect data. | |
[Hourly] [Daily] [Monthly] |
|
0= background data; 1=data possibly affected by local pollution; 2=calibration or invalid data. |
|
Valid (background): 0 Valid: 1 Invalid: 2 |
|
Terminated | |
The air is sampled by a 2m long heated intake at 7 m height above the ground. The air intake is composed by an external (outside building) steel pipe (internally covered by Teflon) and the internal (inside building) Pyrex pipe. A Stainless steel sampling line (lenght 10m) connects the air intake with the high flux sampling pump in front of the sampling loop of the analyzer; a cracking check valve is installed downstream the pump to ensure a sligthly overpressure inside the sampling loop and discharge the excess of flow to vent. |
|
Wind direction: Wind speed: Relative humidity: Precipitation amount: Air pressure: Air temperature: Dew point temperature: Sea water temperature: Sea surface water temperature: Sea water salinity: Sea surface water salinity: |
|
Meteorological data may remain as first provided, even when greenhouse gas data are updated. |
Format | Text (WDCGG Data Format Table, WDCGG Meteorological Data Format Table), NetCDF | ||||
---|---|---|---|---|---|
Relation List (Is Part Of) |
All SF6 data contributed to WDCGG by GAW stations and mobiles by 2024-09-03 All SF6 data contributed to WDCGG by GAW stations and mobiles by 2023-09-13 All SF6 data contributed to WDCGG by GAW stations and mobiles by 2022-09-05 All SF6 data contributed to WDCGG by GAW stations and mobiles by 2021-08-16 All SF6 data contributed to WDCGG by GAW stations and mobiles by 2020-09-28 All SF6 data contributed to WDCGG by GAW stations and mobiles by 2019-09-19 All SF6 data contributed to WDCGG by GAW stations and mobiles by 2018-10-23 |
||||
Geolocation Point |
|