| Background observation | |
| UTC+01:00 | |
| ppb | |
|
9999-12-31 00:00:00 - 9999-12-31 23:59:59: WMO N2O X2006A |
|
|
9999-12-31 00:00:00 - 9999-12-31 23:59:59: Agilent GC6890(Gas chromatography (ECD)) |
|
|
9999-12-31 00:00:00 - 9999-12-31 23:59:59: 7 (m) |
|
| 30 minutes | |
|
every 15 minutes a sample is analyzed alternating between real air and reference standard in order to correct for short time instrumental drifts. molar fraction is calculated from the ratio of the peak heights; reference standard (local working standard) is regolarly checked against NOAA cylinders |
|
| reported data are single point, no average is computed; data validation is evaluated by checking the correct instrumental operation, the spread of the repeated working standard analysis; in case of anomalies, real data are flagged for a deep check and -eventually- removed form the final dataset. results from target cylinder is used to check for long term stability of the whole set up and eventually correct or remove suspect data. | |
|
[Hourly] [Daily] [Monthly] |
|
|
0= background data; 1=data possibly affected by local pollution; 2=calibration or invalid data. |
|
|
Valid (background): 0 Valid: 1 Invalid: 2 |
|
| Terminated | |
|
The air is sampled by a 2m long heated intake at 7 m height above the ground. The air intake is composed by an external (outside building) steel pipe (internally covered by Teflon) and the internal (inside building) Pyrex pipe. A Stainless steel sampling line (lenght 10m) connects the air intake with the high flux sampling pump in front of the sampling loop of the analyzer; a cracking check valve is installed downstream the pump to ensure a sligthly overpressure inside the sampling loop and discharge the excess of flow to vent. |
|
|
Wind direction: Wind speed: Relative humidity: Precipitation amount: Air pressure: Air temperature: Dew point temperature: Sea water temperature: Sea surface water temperature: Sea water salinity: Sea surface water salinity: |
|
|
Meteorological data may remain as first provided, even when greenhouse gas data are updated. |