| NO | 52 |
|---|---|
| Acronym | GERC |
| Name | National Institute of Environmental Research |
| Address 1 | The National Institute of Environmental Research |
| Address 2 | Environmental Research Complex |
| Address 3 | Hwangyeong-ro 42, Seo-gu, Incheon, 22689 |
| Country/Territory | Republic of Korea |
| Website | http://eng.me.go.kr/eng/web/index.do?menuId=46 |
| Name | Jiyoung Kim |
|---|---|
| Prefix | Ms. |
| jykim77@korea.kr | |
| Organization No | 52 |
| Organization acronym | GERC |
| Organization name | National Institute of Environmental Research |
| Organization country/territory | Republic of Korea |
| Address 1 | |
| Address 2 | Environmental Research Complex |
| Address 3 | Hwangyeong-ro 42, Seo-gu, Incheon, 22689 |
| Country/territory | Republic of Korea |
| Tel | +82-32-560-7309 |
| Fax | +82-32-568-2042 |
| Last updated date | 2020-07-28 |
| Name | Eunjung Kim |
|---|---|
| Prefix | Ms. |
| 2929eun@korea.kr | |
| Organization No | 52 |
| Organization acronym | GERC |
| Organization name | National Institute of Environmental Research |
| Organization country/territory | Republic of Korea |
| Address 1 | |
| Address 2 | Environmental Research Complex |
| Address 3 | Hwangyeong-ro 42, Seo-gu, Incheon, 22689 |
| Country/territory | Republic of Korea |
| Tel | +82-32-560-7410 |
| Fax | +82-32-568-2042 |
| Last updated date | 2020-07-28 |
|
|||||||
| Background observation | |||||||
| UTC+09:00 | |||||||
| ppb | |||||||
|
9999-12-31 00:00:00 - 9999-12-31 23:59:59: WMO CH4 X2004 |
|||||||
|
9999-12-31 00:00:00 - 9999-12-31 23:59:59: GC 3800, Varian GC : GC 3800 Detector : FID Detector Temp. : 250 Celsius Oven Temp. : 65 Celsius (15 min) Flow rate : 60 mL/min Column type : Porapak Q 80/100 mesh (1 m× 1/8"× 2 mm SS) Injection volume : 2 mL Valve Temp. : 120 Celsius (Gas chromatography (FID)) |
|||||||
|
9999-12-31 00:00:00 - 9999-12-31 23:59:59: 10 (m) |
|||||||
| Unknown | |||||||
| NOAA04 scale (a gravimetrically-prepared CH4 standard scale) results in CH4 mole fractions that are a factor of 1.0124 greater than previous NOAA methane measurement scale (Dlugokencky et al., 2005). | |||||||
|
1. All data with obvious sampling or instrument operation problems are rejected. 2. The hourly data divide into two groups, background and pollution, by a statistical method. 3. To eliminate local effect, the hourly data in the following wind sectors are rejected. WD=67.5° with wind speed < 22 m/s WD=22.5, 45, 90, 112.5° with wind speed < 11 m/s wind speed < 3 m/s 4. The daily data with the number of hourly data less than 7 are rejected. 5. Daily data are calculated from selected hourly data. 6. Monthly data are calculated using the daily data. |
|||||||
|
[Hourly] 1. All data with obvious sampling or instrument operation problems are rejected. 2. The hourly data divide into two groups, background and pollution, by a statistical method. 3. To eliminate local effect at a pollution group, the hourly data in the following wind sectors are rejected. WD=67.5° with wind speed < 22 m/s WD=22.5, 45, 90, 112.5° with wind speed < 11 m/s wind speed < 3 m/s 4. The daily data with the number of hourly data less than 7 are rejected. [Daily] Daily data are calculated from selected hourly data. [Monthly] Monthly data are calculated using the daily data. |
|||||||
| Temporarily suspended | |||||||
| To track the progress of 'Global Greenhouse Effect' on the Korean peninsula with investigating the concentration of greenhouse gases and their variations. | |||||||
|
Wind direction: Wind speed: Relative humidity: Precipitation amount: Air pressure: Air temperature: Dew point temperature: Sea water temperature: Sea surface water temperature: Sea water salinity: Sea surface water salinity: |
|||||||
|