Login to WDCGG as
Have you completed registration?
Registration and login are needed to download data files.
In line with the GAW Data Policy, users should contact the contributors of all data of interest and propose co-authorship or acknowledgement.


 Organization

NO 28
Acronym HMS
Name Hungarian Meteorological Service
Address 1
Address 2
Address 3 H-1181 Budapest, Gilice tér 39.
Country/Territory Hungary
Website http://www.met.hu/en/idojaras/

 Contact(s)

Name Laszlo Haszpra
Prefix Mr/Dr
Email haszpra.l@gmail.com
Organization No 157
Organization acronym ATOMKI
Organization name Institute for Nuclear Research
Organization country/territory Hungary
Address 1
Address 2 Bem tér 18/C
Address 3 H-4026 Debrecen, Hungary
Country/territory Hungary
Tel +36-30-454-3309
Fax
Last updated date 2024-11-11


 Background observation
 UTC+01:00
 ppm
 9999-12-31 00:00:00 - 9999-12-31 23:59:59: WMO CO2 X2007
 9999-12-31 00:00:00 - 9999-12-31 23:59:59: Siemens Ultramat 3(NDIR)
 9999-12-31 00:00:00 - 9999-12-31 23:59:59: 10 (m)
 Unknown
 Weekly four-point manual calibration using reference gases produced and certified by NOAA CMDL.
 A quadratic response function is fit to each set of calibration gas measurements. The "zero" offset and response function are linearly interpolated in time to obtain values appropriate to calculate CO2 mixing ratio from the instrument response.
 [Hourly] Hourly data are calculated as an arithmetic average from the available data.
 [Daily] Daily data are the arithmetic means of the early afternoon (12-16 h local standard time) hourly mixing ratio values.
 [Monthly] Monthly data are the arithmetic means of the daily data if data are available for more than 1/3 of month. Daily data means the average mixing ration in the early afternoon hours (12-16 h local standard time).
 Flag for 'no data available' 8
Flag for 'above measurement scale' 7
Before 1984 (scale: 304.5 - 404.5 ppm) >404.5 ppm is replaced with 412.5 ppm and flagged as 7
From 1984 (scale: 304.5 - approx. 460 ppm) above measurement scale values are replaced with the actual upper limit of the scale and flagged as 7
 Invalid: 8
 Valid: 0
 Valid: 7
 Temporarily suspended
 Air samples are collected continuously through an air intake at 10 m above the ground. Concentration of CO2 is measured by a Siemens Ultramat 3 non-dispersive infrared (NDIR) analyzer. The air/standard gases to be analyzed is/are saturated by water vapor at the room temperature and cooled to 4°C. In this way the water content of the gas to be analyzed is stable and its influence on the measurement can be compensated.
Detection range 1981-1983 ; 304.5 - 404.5 ppm
1984-1999 ; 304.5 - approx. 460 ppm
Kohler's method for the compensation of the water vapour influence.
 Wind direction:
 Wind speed:
 Relative humidity:
 Precipitation amount:
 Air pressure:
 Air temperature:
 Dew point temperature:
 Sea water temperature:
 Sea surface water temperature:
 Sea water salinity:
 Sea surface water salinity:
Meteorological data may remain as first provided, even when greenhouse gas data are updated.
 
No DOI available

 Related information

Format Text (WDCGG Data Format Table, WDCGG Meteorological Data Format Table), NetCDF
Relation List (Is Part Of) All CO2 data contributed to WDCGG by GAW stations and mobiles by 2024-09-24
All CO2 data contributed to WDCGG by GAW stations and mobiles by 2023-09-13
All CO2 data contributed to WDCGG by GAW stations and mobiles by 2022-09-07
All CO2 data contributed to WDCGG by GAW stations and mobiles by 2021-09-08
All CO2 data contributed to WDCGG by GAW stations and mobiles by 2020-09-28
All CO2 data contributed to WDCGG by GAW stations and mobiles by 2019-09-19
All CO2 data contributed to WDCGG by GAW stations and mobiles by 2018-10-25
Geolocation Point
Latitude (north: +; south: -) 46.9666671753
Longitude (east: +; west: -) 19.5833339691

 GAW Data Policy

"For Scientific purposes, access to these data is unlimited and provided without charge. By their use you accept that an offer of co-authorship will be made through personal contact with the data providers or owners whenever substantial use is made of their data. In all cases, an acknowledgement must be made to the data providers or owners and to the data centre when these data are used within a publication."

 Citation format

This format is an example of the WDCGG standard citation.
Please follow the citation format which the data providers or owners indicate.
Laszlo Haszpra (ATOMKI), Atmospheric CO2 at Kecskemét K-puszta háttérszennyettség-mérő állomás by Hungarian Meteorological Service , dataset published as CO2_KPS_ surface-insitu_HMS_data1 at WDCGG, ver. 2022-02-25-1448 (Reference date*: YYYY/MM/DD)

* As the reference date, please indicate the date you downloaded the files.

 Reference(s)

1  Haszpra, L., 1999: On the representativeness of carbon dioxide measurements. J. of Geophysical Research 104D, 26953-26960.
2  Haszpra, L., 1999: Measurements of atmospheric carbon dioxide at a low elevation rural site in Central Europe.Idojaras 103, 93-105.
3  Haszpra, L., 1995: Carbon dioxide concentration measurements at a rural site in Hungary. Tellus 47B, 17-22.