| NO | 19 |
|---|---|
| Acronym | DWD |
| Name | German Meteorological Service |
| Address 1 | |
| Address 2 | Deutscher Wetterdienst |
| Address 3 | Frankfurter Straße 135, 63067 Offenbach, Germany |
| Country/Territory | Germany |
| Website | http://www.dwd.de/EN/research/observing_atmosphere/composition_atmosphere/hohenpeissenberg/start_mohp_node.html |
| Name | Dagmar Kubistin |
|---|---|
| Prefix | Dr. |
| dagmar.kubistin@dwd.de | |
| Organization No | 19 |
| Organization acronym | DWD |
| Organization name | German Meteorological Service |
| Organization country/territory | Germany |
| Address 1 | |
| Address 2 | |
| Address 3 | Albin-Schwaiger-Weg 10 D-82383 Hohenpeissenberg Germany |
| Country/territory | Germany |
| Tel | +49-69-8062-9740 |
| Fax | +49-69-8062-9707 |
| Last updated date | 2025-10-20 |
| Name | Robert Holla |
|---|---|
| Prefix | |
| robert.holla@dwd.de | |
| Organization No | 19 |
| Organization acronym | DWD |
| Organization name | German Meteorological Service |
| Organization country/territory | Germany |
| Address 1 | |
| Address 2 | |
| Address 3 | Albin-Schwaiger-Weg 10 D-82383 Hohenpeissenberg Germany |
| Country/territory | Germany |
| Tel | +49-69-8062-9741 |
| Fax | +49-69-8062-9707 |
| Last updated date | 2019-10-18 |
| Background observation | |
| UTC+01:00 | |
| Bq/m3 | |
|
9999-12-31 00:00:00 - 9999-12-31 23:59:59: Unknown |
|
|
9999-12-31 00:00:00 - 9999-12-31 23:59:59: TRACERLAB WLM-Plus/ASF-200, S/N 200190(Alpha Detection) |
|
|
9999-12-31 00:00:00 - 9999-12-31 23:59:59: 18 (m) |
|
| hourly | |
| The Working-Level-Monitor uses a mathematical calibration method. Therefore no Radon chamber or comparison with other Working-Level (WL) - Meters are necessary. There is no explicit mathematical formula available because an iterative method is used. The microcomputer of the WL-Monitor integrates in real time the differential equations for 20 different initial sets of the air activities C(Po-218), C(Pb-214), C(Bi-214). That is, the collection and the decay of the filter activity is simulated during the measurement. The results of the 20 simultaneous simulations are 20 pairs of calculated counts N(Po-218) and N(Pb-214). | |
| The data acquisition system gives one hour mean data. Invalid data caused by malfunction or other effects were recognized by comparison/correlation with other trace substances and meteorological data or with the aid of the station logbook and rejected. | |
|
[Hourly] [Daily] [Monthly] |
|
| Only validated data are sent to WDCGG. | |
| Temporarily suspended | |
|
Wind direction: 1 Wind speed: 1 Relative humidity: 1 Precipitation amount: 1 Air pressure: 1 Air temperature: 1 Dew point temperature: 1 Sea water temperature: 0 Sea surface water temperature: 0 Sea water salinity: 0 Sea surface water salinity: 0 |
|
|
Meteorological data may remain as first provided, even when greenhouse gas data are updated. |
| 1 | Stefan Gilge, Measurement of reactive Trace Gases at Hohenpeissenberg as Part of GAW, in "The German Contribution to the WMO/GAW Program": Upon the 225th anniversary of GAW Hohenpeissenberg Observatory, ed. W.Frick, GAW Report 169, 2006 |
|---|