NO | 8 |
---|---|
Acronym | ARSO |
Name | Slovenian Environment Agency |
Address 1 | Vojkova 1b SI-1000 Ljubljana, Slovenia |
Address 2 | |
Address 3 | |
Country/Territory | Slovenia |
Website | http://www.arso.gov.si |
Name | Mateja Gjerek |
---|---|
Prefix | |
mateja.gjerek@gov.si | |
Organization No | 8 |
Organization acronym | ARSO |
Organization name | Slovenian Environment Agency |
Organization country/territory | Slovenia |
Address 1 | Ministrstvo za okolje, podnebje in energijo / Ministry of the Environment, Climate and Energy |
Address 2 | Agencija RS za okolje / Slovenian Environment Agency // Urad za stanje okolja / State of environment Office // Sektor za kakovost zraka / Air Quality Division |
Address 3 | Vojkova 1b, 1001 Ljubljana, p.p |
Country/territory | Slovenia |
Tel | +386 1 478 40 43 |
Fax | +386 1 478 40 52 |
Last updated date | 2024-04-26 |
Name | Tanja Koleša |
---|---|
Prefix | |
tanja.kolesa@gov.si | |
Organization No | 8 |
Organization acronym | ARSO |
Organization name | Slovenian Environment Agency |
Organization country/territory | Slovenia |
Address 1 | Ministrstvo za okolje, podnebje in energijo / Ministry of the Environment, Climate and Energy |
Address 2 | Agencija RS za okolje / Slovenian Environment Agency // Urad za stanje okolja / State of environment Office // Sektor za kakovost zraka / Air Quality Division |
Address 3 | Vojkova 1b, 1001 Ljubljana, p.p |
Country/territory | Slovenia |
Tel | +386 1 478 41 68 |
Fax | +386 1 478 40 52 |
Last updated date | 2024-04-26 |
Name | Primož Dolenc |
---|---|
Prefix | |
primoz.dolenc@gov.si | |
Organization No | 8 |
Organization acronym | ARSO |
Organization name | Slovenian Environment Agency |
Organization country/territory | Slovenia |
Address 1 | Ministrstvo za okolje, podnebje in energijo / Ministry of the Environment, Climate and Energy |
Address 2 | Agencija RS za okolje / Slovenian Environment Agency // Urad za stanje okolja / State of environment Office // Sektor za kakovost zraka / Air Quality Division |
Address 3 | Vojkova 1b, 1001 Ljubljana, p.p |
Country/territory | Slovenia |
Tel | +386 1 478 41 19 |
Fax | +386 1 478 40 52 |
Last updated date | 2024-04-26 |
Background observation | |
UTC+01:00 | |
ppb | |
9999-12-31 00:00:00 - 9999-12-31 23:59:59: APMA 360; Serial nr.: 205003, ID 7062; Horiba(NDIR) |
|
9999-12-31 00:00:00 - 9999-12-31 23:59:59: 10 (m) |
|
1 minute | |
The zero level of the instrument is checked every 24,5 hours. The zero gas from zero air generator and span gas from calibrated bottle (9ppm CO in air) is introduced every 24,5 hours. The span gas from the calibrated bottle and zero air are introduced once every three months on the field against transfer standard-field calibration. The transfer standard is calibrated against laboratory's CRMs every year. Instrument is calibrated in accredited calibration laboratory once per year in 3 points (zero air and primary standard at max.conc and 1/2 max conc.). In addition also 'type approval' tests (short term drift, response time, linearity and repeatability) are performed annually. The certified reference materials (CRMs) are bottles with 7000 and 15000 ppb and are certified at CHMI accredited laboratory once per year and are therefore traceable to international level. Intercomparison in Evaluation of the Laboratory Comparison Exercise for SO2, CO, O3, NO and NO2 is attended every 2 years. The instruments are traceable to CHMI, which ensures tractability to international level. |
|
The raw data from the instrument are collected on the local PC, and stored in the system as one minute raw data. In the 1st level automatic control takes place and all invalid data are flagged. Half an hour data are calculated from valid minute data and transferred to the database on ARSO where 2nd level control and flagging is performed by responsible person. All invalid half an hourly data are eliminated. Valid data coverage must be at least 75%. Flags indicate the status of the data. (valid or invalid) |
|
[Hourly] Hourly data is generated as arithmetic mean of two checked valid half an hour data. [Daily] Daily data is generated as arithmetic mean of valid hourly data. Valid data coverage must be at least 75%. [Monthly] Monthly CO data are calculated by averaging the valid hourly data. Valid data coverage must be at least 75%. |
|
EMEP flags have been used. Definition of flags is available on EMEP homepage / CCC / Data submission / List of flags used in EMEP data base (http://www.nilu.no/projects/ccc/submission.html). | |
Valid: 000 Invalid: 393 Invalid: 999 Invalid: FFF Invalid: 389 Invalid: 391 |
|
Terminated | |
Scientific Aim : To provide data for research and study, and to evaluate long term trends. Sampling Environment : Krvavec monitoring site is situated at the altitude of 1600 m, surrounded mostly by short grass, and under 1600 m partly with coniferous forest. Surrounding slopes and peaks are rocky (limestone). It is located cca. 30 km north of Ljubljana city on mountain crest on the edge of eastern Alps (Kamniško Savinjske alpe – mountain crest with peaks reaching 1500 to 2500 m). Monitoringt site lies above the cold surface air layer, which occurs frequently over the Ljubljana basin during wintertime. Sometimes during anticyclonal situations the inversion layer may rise higher so that the monitoring site lies inside the inversion layer. In heating and skiing period of the year during special weather conditions (weak South to South-East wind) the skiing center and small villages lying beneath Krvavec may slightly contribute to the local air pollution. Description of Instruments Standard ranges: 5, 10, 20, 50 ppm, or 10, 20, 50, 100 ppm Lower detection limit: 0.05 ppm (2 sigma) (5 ppm range) Repeatability: Within ± 1.0% of full scale Accuracy of graduation: Within ± 1.0% of full scale Zero drift: - Larger one of ± 0.1 ppm per day or ± 1.0% of full scale value per day - Larger one of 0.2 ppm per day or ± 2.0% of full scale value per week Span drift: ± 2.0% of full scale value per day ± 3.0% of full scale value per week Response time T90: Within 60 s from system inlet Interference effect: ± 0.3 ppm for 2 vol% H2O and 1000 ppm CO2 Sampling flow rate: Approx. 1.5 L/min Reference : - Operation manual - Ambient CO Monitor - APMA-360, Horiba, Ltd. - Maintenance manual - Ambient CO Monitor - APMA-360, Horiba, Ltd. - Installation manual - Ambient CO Monitor - APMA-360, Horiba, Ltd. Automatic sampling NDIR-absorption Air is sampled through the glass tube at 10 m height. The sampled air is introduced to a CO instrument. |
|
Wind direction: 1 Wind speed: 1 Relative humidity: 1 Precipitation amount: 0 Air pressure: 0 Air temperature: 1 Dew point temperature: 0 Sea water temperature: 0 Sea surface water temperature: 0 Sea water salinity: 0 Sea surface water salinity: 0 |
|
Meteorological data may remain as first provided, even when greenhouse gas data are updated. |
Format | Text (WDCGG Data Format Table, WDCGG Meteorological Data Format Table), NetCDF | ||||
---|---|---|---|---|---|
Relation List (Is Part Of) |
All CO data contributed to WDCGG by GAW stations and mobiles by 2024-09-24 All CO data contributed to WDCGG by GAW stations and mobiles by 2023-09-13 All CO data contributed to WDCGG by GAW stations and mobiles by 2022-09-05 All CO data contributed to WDCGG by GAW stations and mobiles by 2021-08-27 All CO data contributed to WDCGG by GAW stations and mobiles by 2020-09-28 All CO data contributed to WDCGG by GAW stations and mobiles by 2019-09-19 All CO data contributed to WDCGG by GAW stations and mobiles by 2018-10-25 |
||||
Geolocation Point |
|